Remove Stent Remove Stents Remove Thrombosis
article thumbnail

Efficacy of IVUS-guided stent implantation in patients with complex CAD: a meta-analysis based on RCTs

Frontiers in Cardiovascular Medicine

0.85, P = 0.004), target vessel revascularization (TVR) (P = 0.01), target lesion revascularization (TLR) (P = 0.03) and stent thrombosis (ST) (P = 0.002) in the experimental group (IVUS-guidance) was lower than that in the control group (non-IVUS-guidance). The results showed that the incidence of MACE (RR: 0.63, 95% CI: 0.49–0.82,

Stents 52
article thumbnail

Philips launches Duo Venous Stent System for Treatment of Symptomatic Venous Outflow Obstruction

DAIC

and an investigator in the VIVID study , which contributed to the device’s FDA approval – successfully used the Duo Venous Stent System for the first time outside of a clinical trial. Duo Hybrid has a distinct integrated design that combines multiple zones of differing mechanical properties into a single stent [3].

Stents 105
article thumbnail

SMT Publishes Trial Results for Supraflex Cruz Stent

DAIC

Smits and a distinguished team of international researchers, the trial compares the performance of SMT's biodegradable-polymer sirolimus-eluting Supraflex Cruz stent with the biodegradable-polymer Ultimaster Tansei * stent in patients with high bleeding risk (HBR) undergoing abbreviated dual antiplatelet therapy (DAPT).

Stents 52
article thumbnail

Risk factors, prevention, and therapy of intraluminal stent thrombosis in frozen elephant trunk prostheses—what we know so far

Frontiers in Cardiovascular Medicine

In this phenomenon, a thrombus forms within the lumen of the stent graft component of the frozen elephant trunk prosthesis and puts the patient at risk for downstream embolization with visceral or lower limb ischemia. The long-term efficiency of these prophylactic and therapeutic measures has yet to be proven.

Stents 59
article thumbnail

Clinical outcomes and aortic remodeling after Castor single-branched stent-graft implantation for type B aortic dissections involving left subclavian artery

Frontiers in Cardiovascular Medicine

BackgroundThe left subclavian artery (LSA) can be intentionally covered by a stent graft to acquire adequate landing zones for a proximal entry tear near the LSA during thoracic endovascular aortic repair (TEVAR). The Castor single-branched stent graft is designed to treat type B aortic dissection (TBAD) to retain the LSA during TEVAR.

Aortic 52
article thumbnail

Percutaneous Coronary Interventions Using a Ridaforolimus?Eluting Stent in Patients at High Bleeding Risk

Journal of the American Heart Association

Drug‐eluting stents have been shown to be superior to bare‐metal stents in patients with HBR, even when patients were given abbreviated periods of dual antiplatelet therapy (DAPT). Short DAPT has not been evaluated with the EluNIR ridaforolimus‐eluting stent. presented with acute coronary syndrome; 33.7%

Stents 40
article thumbnail

Clinical outcomes with thin versus thick strut polymer-free biolimus-coated stents at 3 years

Open Heart

Background For high bleeding-risk patients (HBR) undergoing percutaneous coronary intervention (PCI), the LEADERS FREE (LF) and LEADERS FREE II (LF II) trials established the safety and efficacy of a stainless steel polymer-free biolimus-coated stent (SS-BCS) with 30 days of dual antiplatelet treatment (DAPT).

Stents 40