Remove Plaque Remove Stenosis Remove Stents
article thumbnail

HonorHealth Research Institute First in Southwest to Implant New Stroke Prevention Stent

DAIC

The Neuroguard Integrated Embolic Protection (IEP) system is an experimental treatment for carotid artery stenosis, also known as carotid artery disease, a condition in which fatty-waxy deposits known as plaque builds up and blocks the normal flow of blood in the large arteries on either side of the neck. Designed by Raleigh, N.C.-based

Stent 111
article thumbnail

William M. Feinberg Lecture: Asymptomatic Carotid Stenosis: Current and Future Considerations

Stroke Journal

Asymptomatic high-grade carotid stenosis is an important therapeutic target for stroke prevention. Since then, transfemoral/transradial carotid stenting and transcarotid artery revascularization have emerged as alternatives to endarterectomy for revascularization.

article thumbnail

Intravascular Ultrasound (IVUS) for Coronary Intervention

All About Cardiovascular System and Disorders

IVUS Measurements Measurements include the measurement of lumen, plaque, calcium, remodeling, stent length and volumetric measurements. Plaque morphology assessment with IVUS Plaque morphology can be assessed in terms of its geometry and echogenicity. Thrombus and intimal hyperplasia can be noted.

article thumbnail

Abstract TMP68: Proximal Balloon Occlusion With Forced Aspiration (POWER) Technique Should Be Effective in Preventing Distal Microembolization During Carotid Artery Stenting With the Filter Protection Device

Stroke Journal

Purpose:Since the balloon protection device became unavailable in Japan three years ago, the DWI-positive rate after carotid artery stenting (CAS) has increased. Symptomatic stenosis (63.9% Stroke, Volume 55, Issue Suppl_1 , Page ATMP68-ATMP68, February 1, 2024. vs. 94.7%, p<0.05) was more common in the with-POWER group.

Stent 40
article thumbnail

Abstract 191: Simulating Intracranial Stenosis: A Methodological Approach In An In?Vitro Neurovascular Model

Stroke: Vascular and Interventional Neurology

3% sodium alginate solution was cast into a stenosis mold and crosslinked in a 40% calcium chloride. The deformable gel constituted an 8mm long replaceable stenotic segment at the level of M1‐MCA simulating an atherosclerotic plaque with a 0.5mm internal diameter. An initial stenosis flow rate was registered with a value of 8.5 ± 5.33

article thumbnail

Elixir Medical Granted FDA Breakthrough Device Designation for DynamX Bioadaptor

DAIC

The breakthrough designation, according to the Milpitas, CA-based technology company, is for an indication to improve coronary luminal diameter, restore hemodynamic modulation, and reduce plaque progression in patients with symptomatic ischemic heart disease due to discrete de novo native coronary artery lesions. of the U.S. population.

article thumbnail

Endovascular intervention with intravascular ultrasound guidance of very early dissection complication in transplant renal artery: a case report and literature review

Frontiers in Cardiovascular Medicine

Doppler ultrasonography performed a day after the operation showed an increase in systolic blood velocity, with no observed urine output and raising a suspicion of arterial anastomotic stenosis. The transplant renal artery lesion was intervened with a stent.