Abstract 172: Outcomes and Complications of Stent?Assisted Aneurysm Repair in Acute Subarachnoid Hemorrhage

Stroke: Vascular and Interventional Neurology

IntroductionThe use of detachable coils for endovascular embolization of cerebral aneurysms has become a safe and effective alternative to direct surgical clipping in patients with ruptured aneurysmal subarachnoid hemorrhage. The post‐procedural complication rate proved to be higher than in non‐ruptured stent‐assisted coiling.

article thumbnail

Abstract 169: Antiplatelet regimens after pseudoaneurysm embolization with phosphorylcholine coated flow diverters: a series of 180 cases

Stroke: Vascular and Interventional Neurology

3 The third‐generation iteration of the Pipeline Embolization Device (PED) incorporates Shield technology, a phosphorylcholine coating designed to reduce thrombogenicity via mimicry of native cell membranes.4 One patient had a new intraparenchymal hemorrhage, but no appreciable deficit.

article thumbnail

Abstract WMP87: Characteristics and Outcome of Endovascular Treatment for Intracranial Atherosclerotic Occlusion: Comparison With Cardiogenic Cerebral Embolism in the K-NET Registry

Stroke Journal

The purpose of this study was to compare the outcomes of EVT for ICAD with those of cardiogenic cerebral embolism (CE) based on real-world data from a multicenter, prospective registry study (K-NET registry) involving 40 centers in Japan.Methods:The K-NET study enrolled 3187 EVTs in 2018-2021, of which 358 (11%) were ICAD and 1870 (59%) were CE.

article thumbnail

Abstract 180: A Prospective, Single?Center Study Appraising Aneurysm Embolization using the Balt Optima™ Coil System (APPLY Study)

Stroke: Vascular and Interventional Neurology

Cases of unruptured intracranial aneurysms (UIA) are estimated to affect roughly 3% of the general population and aneurysmal subarachnoid hemorrhage (aSAH) have an incidence of 8 to 9 people per 100,000.

article thumbnail

Abstract 037: Aneurysm Occlusion Rates with WEB Treatment: Single?Institution Study and Review

Stroke: Vascular and Interventional Neurology

Statistical analysis was performed to identify predictors of inadequate occlusion.ResultsA total of 51 patients underwent endovascular embolization using the WEB device with a mean follow‐up of 14.9 Ruptured aneurysmal subarachnoid hemorrhage accounted for 15.7% (8/51) of all patients. There were no hemorrhagic complications.

article thumbnail

Abstract 236: Effects of intravenous thrombolysis on thrombectomy outcomes: a systematic review and meta?analysis

Stroke: Vascular and Interventional Neurology

However, IVT's efficacy on stent retriever (SR) and aspiration thrombectomy (ASP) outcomes specifically remain unclear. Stroke: Vascular and Interventional Neurology, Volume 3, Issue S2 , November 1, 2023. IntroductionEfficacy and safety of intravenous thrombolysis (IVT) in patients undergoing mechanical thrombectomy (MT) is still debatable.

article thumbnail

FDA Announces Medos International Sàrl Recall of Cerenovus CEREBASE DA Guide Sheath due to Cracking of the Distal Catheter Shaft

DAIC

This catheter is designed to help deliver interventional devices into the blood vessels in the brain, allowing doctors to place devices like stents or coils, to treat neurovascular diseases and conditions. This type of catheter is commonly used in procedures where precise navigation and access to blood vessels in the brain are required.