Remove Aortic Remove Stenosis Remove Tricuspid
article thumbnail

Eagle’s Eye View: Sacubitril/Valsartan in Decompensated Heart Failure; Discordant Aortic Stenosis and Transcatheter Treatment of Tricuspid Valve Regurgitation

American College of Cardiology

Eagle looks at sacubitril/valsartan in patients hospitalized with decompensated heart failure, then examines the prevalence and outcomes of patients with discordant high gradient aortic stenosis.

article thumbnail

Progression of aortic stenosis after an acute myocardial infarction

Open Heart

Background Myocardial infarction (MI) has been shown to induce fibrotic remodelling of the mitral and tricuspid valves. It is unknown whether MI also induces pathological remodelling of the aortic valve and alters aortic stenosis (AS) progression. vs –0.04±0.04 cm 2 /m 2 /year; p=0.004).

article thumbnail

Outcomes Following Transcatheter Aortic Valve Replacement for Aortic Stenosis in Patients With Type 0 Bicuspid, Type 1 Bicuspid, and Tricuspid Aortic Valves

Circulation: Cardiovascular Interventions

BACKGROUND:Data concerning the outcomes of transcatheter aortic valve replacement in type 0 bicuspid aortic stenosis (AS) are scarce. Ascending aortic diameter was the single predictor of 1-year mortality in type 0 bicuspid patients (hazard ratio, 1.59 [95% CI, 1.03–2.44];P=0.035). Poverall=0.522; 1 year: 10% versus 2.3%

article thumbnail

Artificial intelligence-enabled phenotyping of patients with severe aortic stenosis: on the recovery of extra-aortic valve cardiac damage after transcatheter aortic valve replacement

Open Heart

Objective A novel artificial intelligence-based phenotyping approach to stratify patients with severe aortic stenosis (AS) prior to transcatheter aortic valve replacement (TAVR) has been proposed, based on echocardiographic and haemodynamic data. ±15.8 ±15.1 mm Hg, p value: 0.0079). to 84.7%) and 74.6% (95% CI 65.9%

article thumbnail

AISAP’s CARDIO AI-powered Diagnostic Assessment Software Receives FDA Clearance

DAIC

Standalone performance for significant major valve disease pathology (aortic stenosis and regurgitation and mitral and tricuspid regurgitation) had a 93 percent sensitivity and 93 percent specificity.

article thumbnail

Quantitative fluid overload in severe aortic stenosis refines cardiac damage and associates with worse outcomes

European Journal of Heart Failure

Assessment of fluid overload identifies aortic stenosis (AS) patients at high risk and treatment of fluid overload may potentially improve the post-interventional clinical course. TAVI, transcatheter aortic valve implantation. FO by BIS was defined as ≥1.0 L L = euvolaemia).

article thumbnail

Tricuspid regurgitation: Frequency, clinical presentation, management and outcome among patients with severe left?sided valvular heart disease in Europe. Insights from the ESC?EORP Valvular Heart Disease II survey

European Journal of Heart Failure

Tricuspid regurgitation (TR): frequency, clinical presentation, management and outcome among patients with severe left-sided valvular heart disease in Europe. ESC-EORP, European Society of Cardiology-EURObservational Research Programme; TV, tricuspid valve.