article thumbnail

PO-03-125 FOCAL ATRIAL TACHYCARDIAS ORIGINATING FROM THE AORTA-MITRAL CONTINUTY: ANATOMY CHARACTERISTICS AND ELECTROPHYSIOLOGICAL CHARACTERISTICS

HeartRhythm

Hence, the electrophysiological and ablation target characteristics are poorly described. Focal AT at the aorta-mitral annulus conjunction (AMC) is uncommon.

article thumbnail

Atypical Atrial Flutter: Electrophysiological Characterization and Effective Catheter Ablation

Journal of Cardiovascular Electrophysiology

The ECG pattern is poorly predictive of circuit anatomy but may still provide mechanistic insight. Recent progress in technology and clinical electrophysiology has led to detailed characterization of re-entry circuits and effective ablation strategies.

article thumbnail

Features and Electrophysiological Behavior of AV Nodal Structures Potential Recorded in Humans

HeartRhythm

Atrioventricular nodal reentry tachycardia (AVNRT), identified as the most prevalent form of regular tachycardia in humans,3 exhibits a strong relationship with the anatomy and physiology of the AV node (AVN) and junction. Despite the temporal distance, Koch's triangle and pyramid remain a repository of unresolved mysteries.

article thumbnail

Boston Scientific Receives FDA Approval for FARAPULSE Pulsed Field Ablation System

DAIC

said Nick Spadea-Anello, president, Electrophysiology, Boston Scientific. director of electrophysiology, Mount Sinai Fuster Heart Hospital , New York. physicians and patients alike," Reddy added. These configurations reinforce ease-of-use for physicians and promote reproducible procedures between operators.

Ablation 111
article thumbnail

PO-05-033 PATIENT-SPECIFIC BIATRIAL MODELLING FRAMEWORK FOR PREDICTING ATRIAL FIBRILLATION OUTCOMES

HeartRhythm

Predicting patient-specific responses to treatment and guiding therapy requires a framework that integrates personalised anatomy, fibrosis and electrophysiological data. However, it is challenging to perform on clinical timescales and at scale.

article thumbnail

PO-01-162 DIVERGENT PATTERNS: CONTRASTING VOLTAGE AND CALCIUM ALTERNANS BETWEEN FISH AND HUMAN HEARTS

HeartRhythm

While zebrafish (ZF) and human hearts (HH) differ in size and anatomy, similarities in cellular structure and electrophysiology have made ZF an attractive model for arrhythmia research. However, scenarios when ZF is an adequate model for human heart studies have not been clearly established.

Anatomy 40
article thumbnail

Abbott Announces First Global Procedures in a Clinical Trial of its Volt Pulsed Field Ablation System to Treat Patients with Abnormal Heart Rhythms

DAIC

Instead of heat or extreme cold, PFA uses high energy electrical pulses to destroy the cells causing abnormal heart rhythms, which can reduce the risk of damaging adjacent tissue in patients with complex disease or anatomy. chief medical officer of Abbott's electrophysiology business.