article thumbnail

Transcatheter Mitral Valve Replacement With Atrial Fixation for Treatment of Atrial Functional Mitral Regurgitation

Circulation: Cardiovascular Interventions

At 30 days, 11 of 12 surviving patients had an available echocardiogram; mitral regurgitation severity was trace/none in 90.9% (10/11) and mild in 9.1% (1/11).CONCLUSIONS:The CONCLUSIONS:The AltaValve system shows promising early procedural and clinical results for the unique anatomy of patients with atrial functional mitral regurgitation.

article thumbnail

Right Heart Catheterization in Tetralogy of Fallot

All About Cardiovascular System and Disorders

Diagnostic cardiac catheterization may be needed especially in tetralogy of Fallot with pulmonary atresia, to assess the pulmonary anatomy, including size and distribution of peripheral pulmonary arteries. Another important role is for detection of coronary anomalies, which can also be seen on echocardiogram sometimes.

article thumbnail

Autus Valve | The expandable artificial heart valve

Wellnest

To their success, they discovered that this device could be fitted and expanded in sync with the growth of the heart anatomy. Before implantation, doctors can adjust the valve diameter to match the patient’s heart anatomy.

article thumbnail

Different leadless pacemakers working in harmony (Aveir in the atrium/Micra AV2 in the ventricle) in a patient with dextrocardia and double outlet right ventricle after high?risk infected device extraction

Journal of Cardiovascular Electrophysiology

Methods We present the first described case of using two leadless pacing systems manufactured by separate companies implanted within the same patient to provide atrial and ventricular pacing due to complex congenital anatomy. Laser-lead extraction and temporary atrial pacemaker placement was performed.

article thumbnail

Abstract 4140682: Clinical Case: Flipping the Script: Tackling CAD in Dextrocardia During Cardiac Catheterization

Circulation

Although he had a normal echocardiogram and stress test a year ago at a different hospital, due to his symptoms and intermediate-high risk probability of coronary artery disease (CAD), the decision was made to proceed with a cardiac catheterization using a trans-radial approach with a horizontal sweep technique.

article thumbnail

SPONSORED CONTENT: Unveiling the Future of Cardiovascular Workflow

DAIC

Using machine learning algorithms, InView’s Categorical Hanging Image Protocol(CHIP) automatically organizes images by anatomy and pathology categories to intelligently display or “hang” current and prior studies in a way that significantly improves the efficiency of single or multi-modality image review. As well, by incorporating Us2.ai’s

article thumbnail

Basics of Echocardiography

All About Cardiovascular System and Disorders

The image shown here is an animated 2 dimensional echocardiogram. This one is an older mode known as time-motion mode or M-Mode echocardiogram. A good knowledge of the anatomy of the heart is needed for interpretation of images from each view. Unlike the previous 2 dimensional imaging, this is a single dimensional imaging.