Remove Ablation Remove Electrophysiology Remove Pulmonary
article thumbnail

Abbott Receives CE Mark for Pulsed Field Ablation System

DAIC

1,2 People living with AFib face an increased risk of stroke, heart failure and death, and many rely on cardiac ablation to treat the condition effectively. The trial showed the Volt PFA System achieved pulmonary vein isolation (PVI) the method of destroying tissue causing a patient's AFib in 99.1% Procedural flexibility.

article thumbnail

Trial: Artificial Intelligence-guided Cardiac Ablation Procedure Improves Treatment of Atrial Fibrillation

DAIC

In particular, the study showed superiority in the percentage of patients that achieved freedom from atrial fibrillation (AF) with or without anti-arrhythmic drugs at 12 months after a tailored cardiac ablation guided by AI in combination with PVI when compared to PVI alone. tim.hodson Fri, 02/14/2025 - 09:57 Feb. adult population.

article thumbnail

An approach to fluoroless radiofrequency atrial fibrillation ablation

Frontiers in Cardiovascular Medicine

Pulmonary vein isolation (PVI) is the most effective treatment for rhythm control. Additional advantages include providing electrophysiology lab personnel with a lead-free working environment and avoiding radiation exposure for both patients and physicians. It has initially been performed with fluoroscopic catheter guiding.

article thumbnail

Shorten the Blanking Period After Atrial Fibrillation Ablation, Experts Say

DAIC

Based on continuous monitoring of early recurrence of atrial tachyarrhythmia immediately after patients have undergone atrial fibrillation ablation, Musat et al. Early recurrence of atrial tachyarrhythmia (ERAT) is commonly seen following catheter ablation of AF, with reported incidences of up to 61% in the first three months.

article thumbnail

Distribution Variance of Focal Atrial Tachycardia Foci and Long‐Term Outcomes After Ablation: Experience From Two Chinese Centers

Journal of Cardiovascular Electrophysiology

Distribution Variance of Focal Atrial Tachycardia Foci and Long-Term Outcomes After Ablation. We aimed to evaluate age differences in foci and factors influencing recurrence after radiofrequency catheter ablation in adult and juvenile patients with FAT. After a mean follow-up of 47.2 months, FAT recurred in 57 patients.

article thumbnail

Boston Scientific Receives FDA Approval for FARAPULSE Pulsed Field Ablation System

DAIC

Food and Drug Administration (FDA), has granted approval to Boston Scientific for its FARAPULSE Pulsed Field Ablation System. A company statement reported that its PFA System is indicated for the isolation of pulmonary veins in the treatment of drug-refractory, recurrent, symptomatic, paroxysmal (i.e.,

Ablation 111
article thumbnail

Late-breaking Clinical Trial Results from FARADISE, adMIRE Study and Advent Trial at Heart Rhythm 2024 Highlight Pulsed Field Ablation Developments for Atrial Fibrillation Treatment

DAIC

During its Annual Conference, HRS 2024, the Heart Rhythm Society (HRS) announced findings from three new studies demonstrating the safety and efficacy of pulsed field ablation (PFA), a nonthermal ablation treatment for patients with atrial fibrillation (AF). See full findings from the FARADISE, admIRE Study, and Advent Trial here.