Remove 2025 Remove Aneurysm Remove Stents
article thumbnail

Abstract WP258: Aneurysm neck width reduces flow diversion in new generation stent placed at high curvature ICA segment

Stroke Journal

Stroke, Volume 56, Issue Suppl_1 , Page AWP258-AWP258, February 1, 2025. Introduction:Surpass Evolve (SE) is an updated flow diverter stent. While shown to be effective and safe for treating intracranial aneurysms (IA), blood flow analysis is still limited. For each case, a SE device measuring 3.25 respectively).

article thumbnail

Abstract WP43: Factors related to major recanalization after second coiling for recanalized aneurysms: a multicenter experience over 20 years during long-term follow-up

Stroke Journal

Stroke, Volume 56, Issue Suppl_1 , Page AWP43-AWP43, February 1, 2025. Objective:Recanalized aneurysms may still recanalize despite a second coiling to prevent rupture. Factors related to recanalization following a second coiling for recanalized aneurysms have not yet been fully explored.

article thumbnail

Abstract TP247: Iatrogenic Cervical Artery Dissections during Endovascular Interventions

Stroke Journal

Stroke, Volume 56, Issue Suppl_1 , Page ATP247-ATP247, February 1, 2025. Of the 32 patients, 9(28.1%) had dissection with diagnostic angiograms, 6(18.8%) endovascular thrombectomy, 15(46.9%) aneurysm treatment, and 2(6.3%) angioplasty with or without stenting. Only 4(12.5%) were treated with hyperacute stenting.

Stent 40
article thumbnail

Abstract DP37: Role of Light Transmission Aggregometry values predict diffusion weighted image change after Stent assisted Coil Embolization for Intracranial Aneurysm: a retrospective propensity score-matched study

Stroke Journal

Stroke, Volume 56, Issue Suppl_1 , Page ADP37-ADP37, February 1, 2025. Object:The introduction of antiplatelet agents is essential in stent-assisted coil embolization (SACE) for the treatment of intracranial aneurysms, and preoperative drug efficacy assessment is important in reducing the risk of ischemic complications.

article thumbnail

Abstract 80: Predictors of Procedural Outcome after Surface-Modified Flow Diverter Treatment for Intracranial Aneurysms: An Update from the INSPIRE-A Registry

Stroke Journal

Stroke, Volume 56, Issue Suppl_1 , Page A80-A80, February 1, 2025. Introduction:Although flow diverters (FD) are a long-established treatment-option for brain aneurysms, the evidence of data associated with therapy success is still based on relatively small heterogeneous studies. Median diameter and neck width of aneurysms were 7.2