HonorHealth Research Institute First in Southwest to Implant New Stroke Prevention Stent

DAIC

The Neuroguard Integrated Embolic Protection (IEP) system is an experimental treatment for carotid artery stenosis, also known as carotid artery disease, a condition in which fatty-waxy deposits known as plaque builds up and blocks the normal flow of blood in the large arteries on either side of the neck. Designed by Raleigh, N.C.-based

Stent 111
article thumbnail

One-Year BIONETIC-I Study Results Show Safety and Effectiveness of Iliac Artery Treatment With BIOTRONIK’s Dynetic-35 Cobalt Chromium Balloon-Expandable Stent System

DAIC

milla1cf Thu, 05/30/2024 - 10:14 May 30, 2024 — B iotronik announced the presentation of the 12-month results from the BIONETIC-I study this week at LINC 2024. stenosis in the target lesion. Presented at: LINC 2024; May 30, 2024; Leipzig, Germany. At baseline, 12.5% Brodmann M.

Stent 69
article thumbnail

Emergent Large Vessel Occlusion due to Intracranial Stenosis: Identification, Management, Challenges, and Future Directions

Stroke Journal

Stroke, Volume 55, Issue 2 , Page 355-365, February 1, 2024. This comprehensive literature review focuses on acute stroke related to intracranial atherosclerotic stenosis (ICAS), with an emphasis on ICAS-large vessel occlusion.

article thumbnail

Abstract TP174: Balloon Expandable Stents versus Self-Expanding Stents for Treatment of Intracranial Arterial Stenosis: A Systematic Review and Meta-Analysis

Stroke Journal

Stroke, Volume 55, Issue Suppl_1 , Page ATP174-ATP174, February 1, 2024. The standardized mean difference (SMD) for post-procedure stenosis (%) was significantly lower (SMD: -0.52, 95% confidence interval [CI]: -0.79 Data were extracted from relevant studies found through a search of PubMed, Scopus, and Web of Science until May 2023.

Stent 40
article thumbnail

OPTILOW: A Low‐Profile Approach for Implanting Optimus‐L Stents in Infants and Children

Journal of the American Heart Association

Stent performance was assessed.ResultsWe identified 28 patients (67.8% Percentage of stenosis was 50% (IQR, 36%58%). The procedures mostly used 7 Fr sheaths for stents on 6, 7, and 8 mm balloons and 8 Fr sheaths for 9, 10, 12 mm balloons. Median stent expansion percentage was 95% (IQR, 90%96%). kg (IQR, 9.116.4).

Stent 45
article thumbnail

Elixir Medical Granted FDA Breakthrough Device Designation for DynamX Bioadaptor

DAIC

Image courtesy: Getty Images christine.book Tue, 06/18/2024 - 11:07 June 18, 2024 — Elixir Medical has announced the company’s novel bioadaptive implant, DynamX Sirolimus-Eluting Coronary Bioadaptor System, has been granted Breakthrough Device Designation by the U.S. Stent Related Adverse Events greater than 1 Year After PCI.

article thumbnail

Optimal Minimal Stent Area and Impact of Stent Underexpansion in Left Main Up-Front 2-Stent Strategy

Circulation: Cardiovascular Interventions

Circulation: Cardiovascular Interventions, Volume 17, Issue 1 , Page e013006, January 1, 2024. BACKGROUND:We previously reported the use of minimal stent area to predict angiographic in-stent restenosis after drug-eluting stent implantation for unprotected left main (LM) disease. P=0.15), 8.3 P=0.02), and 5.7 P=0.15), 8.3

Stent 40